<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Asinfarma: Asesoría Industrial Farmacéutica &#187; Muestreo de materias primas</title>
	<atom:link href="http://www.fernandotazon.com.es/category/8-quality-control/muestreo-de-materias-primas/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.fernandotazon.com.es</link>
	<description>La nueva generación de asesoría industrial</description>
	<lastBuildDate>Mon, 16 Jan 2012 09:33:52 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>Análisis de Riesgos en Control de Calidad</title>
		<link>http://www.fernandotazon.com.es/2010/10/27/analisis-de-riesgos-en-control-de-calidad/</link>
		<comments>http://www.fernandotazon.com.es/2010/10/27/analisis-de-riesgos-en-control-de-calidad/#comments</comments>
		<pubDate>Wed, 27 Oct 2010 14:04:54 +0000</pubDate>
		<dc:creator>Fernando</dc:creator>
				<category><![CDATA[ADMINISTRACIÓN SANITARIA]]></category>
		<category><![CDATA[Certificados de Análisis]]></category>
		<category><![CDATA[Coaching]]></category>
		<category><![CDATA[Cualificación Equipos de Laboratorio]]></category>
		<category><![CDATA[Cursos in company]]></category>
		<category><![CDATA[Farmacopea Europea]]></category>
		<category><![CDATA[Formadores Internos]]></category>
		<category><![CDATA[GMP - GOOD MANUFACTURING PRACTICE]]></category>
		<category><![CDATA[GMP del Siglo XXI]]></category>
		<category><![CDATA[ICH Q11]]></category>
		<category><![CDATA[ICH Q9]]></category>
		<category><![CDATA[Impurezas]]></category>
		<category><![CDATA[Laboratorio de Control]]></category>
		<category><![CDATA[Microbiología rápida]]></category>
		<category><![CDATA[Muestreo de materias primas]]></category>
		<category><![CDATA[OOS]]></category>
		<category><![CDATA[OOT]]></category>
		<category><![CDATA[QUALITY CONTROL]]></category>
		<category><![CDATA[RISK MANAGEMENT]]></category>
		<category><![CDATA[Risk Management Plan]]></category>
		<category><![CDATA[Risk-based Manufacturing]]></category>
		<category><![CDATA[Risk-based Quality Control]]></category>
		<category><![CDATA[Seminarios de Formación Especializada]]></category>
		<category><![CDATA[TRAINING MANAGEMENT 2.0]]></category>
		<category><![CDATA[Test de esterilidad]]></category>
		<category><![CDATA[USP]]></category>
		<category><![CDATA[análisis de riesgos]]></category>
		<category><![CDATA[controles en proceso]]></category>
		<category><![CDATA[cualificación-de-instrumentos-analiticos]]></category>
		<category><![CDATA[EMA]]></category>
		<category><![CDATA[FDA]]></category>
		<category><![CDATA[Inspección GMP]]></category>
		<category><![CDATA[microbiología-rápida]]></category>
		<category><![CDATA[quality-risk-management]]></category>
		<category><![CDATA[risk-based quality control]]></category>

		<guid isPermaLink="false">http://www.fernandotazon.com.es/?p=1742</guid>
		<description><![CDATA[<img class="alignleft size-thumbnail wp-image-1754" title="RISK-BASED QUALITY CONTROL" src="http://www.fernandotazon.com.es/wp-content/uploads/2010/10/Inspección5-128x190.jpg" alt="" width="90" height="134" />]]></description>
			<content:encoded><![CDATA[<p><img class="alignleft size-thumbnail wp-image-1754" title="RISK-BASED QUALITY CONTROL" src="http://www.fernandotazon.com.es/wp-content/uploads/2010/10/Inspección5-128x190.jpg" alt="" width="102" height="151" />El <span style="color: #0000ff;"><strong>8 de Noviembre</strong></span> organizaremos en Barcelona el <strong>Seminario de Formación Especializada </strong>sobre <span style="color: #0000ff;"><strong><em>Risk-based Quality Control</em></strong></span>, dentro de nuestro programa de difusión de las nuevas estrategias industriales que posibilitan las GMP del Siglo XXI.</p>
<p>Para la industria farmacéutica, el poder equilibrar la carga de trabajo necesaria, el nivel de formalidad requerido y la cantidad de documentación a generar, con el nivel real de riesgo del producto, método o instrumento, supone un importante ahorro en recursos y permite focalizar los escasos medios disponibles sobre los factores críticos que aportan valor.</p>
<p>Como en eventos anteriores, en este seminario volvemos a contar con la presencia de ponentes de primer nivel:</p>
<ol>
<li><span style="color: #0000ff;"><strong>Salvador Cassany</strong></span>, <em>C</em><em>ap del Servei de Control Farmacèutic i Productes Sanitaris, del <a title="Departament de Salut" href="http://www.gencat.cat/salut/" target="_blank">Departament de Salut de la Generalitat de Catalunya</a></em>, que nos presentará la visión de la inspección farmacéutica.</li>
<li><span style="color: #0000ff;"><strong>Ana Vila-Ferran</strong></span>, <em>Directora General de <a title="Micro-Bios" href="http://www.laboratoriomicro-bios.com/" target="_blank">MICRO-BIOS</a></em>, que hablará sobre la Cualificación de Instrumentos Analíticos.</li>
<li><span style="color: #0000ff;"><strong>Dolors Solsona</strong></span>, <em>Directora de Control de Calidad de <a title="ESTEVE" href="http://www.esteve.es/EsteveFront/EST.do" target="_blank">ESTEVE</a></em>, que aplicará el análisis de riesgos al tratamiento de OOS.</li>
<li><span style="color: #0000ff;"><strong>Rogelio Cortés</strong></span>, <em>Responsable del Laboratorio de Microbiología de <a title="ALCON" href="http://www.alcon.es/es/index.asp" target="_blank">ALCON</a></em>, que demostrará como aplicarlo en microbiología rápida.</li>
<li><strong><span style="color: #0000ff;">Daniel Pons</span>, </strong><em>Responsable QA Compliance &amp; Regulatory de <a title="Novartis Home Page" href="http://www.novartis.es/portales/web/es/apartados/menuprincipal/home.html" target="_blank">NOVARTIS</a></em>, que explicará la implementación en los controles en proceso.</li>
</ol>
<p>Entre los asistentes, ya contamos con la presencia de laboratorios tan importantes como <a title="Fresenius Kabi España" href="http://www.fresenius-kabi.es/" target="_blank">FRESENIUS KABI ESPAÑA</a>, <a title="Bioiberica" href="http://www.bioiberica.com/" target="_blank">BIOIBERICA</a>, <a title="Inibsa Home Page" href="http://www.inibsa.com/spanish/index.html" target="_blank">INIBSA</a>, <a title="Uriach Home Page" href="http://www.uriach.com/" target="_blank">URIACH</a>, <a title="Praxis Pharmaceutical" href="http://www.grupo-praxis.com/" target="_blank">PRAXIS PHARMACEUTICAL</a>, <a title="Lesvi" href="http://www.invent-farma.com/" target="_blank">LESVI</a>, <a title="Pharmaprojects" href="http://www.farmaprojects.es/es/index.php" target="_blank">FARMAPROJECTS</a>, <a title="Menarini" href="http://www.menarini.es/" target="_blank">MENARINI</a>, <a title="Laboratorios Leti" href="http://www.leti.com/es/" target="_blank">LETI</a>, <a title="Alcon Home Page" href="http://www.alcon.es/es/index.asp" target="_blank">ALCON</a>, <a title="GP Pharm Home Page" href="http://www.gp-pharm.com/" target="_blank">GP PHARM</a>, <a title="Pierre Fabre" href="http://www.pierre-fabre.com/es/accueil/0,6951,20146147_0_0_es_ES_0,00.html?vid=20147936" target="_blank">PIERRE FABRE</a>, <a title="HIPRA" href="http://www.hipra.com/wps/portal/web/inicio/home/!ut/p/c5/04_SB8K8xLLM9MSSzPy8xBz9CP0os3gDU8dASydDRwMLpwADA09PC2cXA3MnA4tQE_1wkA6cKgz8jaDyOICjgb6fR35uqn5Bdnaao6OiIgDxkhFD/dl3/d3/L2dBISEvZ0FBIS9nQSEh/" target="_blank">HIPRA</a>, <a title="CRISTAL PHARMA" href="http://www.crystalpharma.com/es/" target="_blank">CRISTAL PHARMA</a>, <a title="COMBINO PHARM" href="http://www.combino-pharm.es/es/index.php" target="_blank">COMBINO PHARM</a>, <a title="KYMOS PHARMA" href="http://www.kymos.com/" target="_blank">KYMOS PHARMA SERVICES</a>, <a title="Uriach Home Page" href="http://www.uriach.com/" target="_blank">URQUIMA</a>, <a title="GSK" href="http://www.gsk.com/" target="_blank">GLAXOWELLCOME</a>, <a title="Laboratorios ERN" href="http://www.ern.es/" target="_blank">ERN</a>, <a title="Ferrer Group Home Page" href="http://www.ferrergrupo.com/" target="_blank">FERRER INTERNACIONAL</a>, <a title="ESTEVE" href="http://www.esteve.es/EsteveFront/EST.do" target="_blank">ESTEVE</a>, <a title="Inibsa Home Page" href="http://www.inibsa.com/spanish/index.html" target="_blank">INIBSA</a>, e <a title="INTERVET" href="http://www.intervet.es/" target="_blank">INTERVET</a>.</p>
<p><span style="color: #ff0000;"><strong><a title="Programa Formación Risk-based Quality Control" href="http://www.fernandotazon.com.es/wp-content/uploads/2010/08/Programa-RBQC.pdf" target="_blank">AQUÍ PODÉIS CONSULTAR EL PROGRAMA COMPLETO DEL SEMINARIO</a></strong></span></p>
]]></content:encoded>
			<wfw:commentRss>http://www.fernandotazon.com.es/2010/10/27/analisis-de-riesgos-en-control-de-calidad/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Formación Risk based Quality Control</title>
		<link>http://www.fernandotazon.com.es/2010/08/29/formacion-risk-based-quality-control/</link>
		<comments>http://www.fernandotazon.com.es/2010/08/29/formacion-risk-based-quality-control/#comments</comments>
		<pubDate>Sun, 29 Aug 2010 12:43:07 +0000</pubDate>
		<dc:creator>Fernando</dc:creator>
				<category><![CDATA[ADMINISTRACIÓN SANITARIA]]></category>
		<category><![CDATA[Coaching]]></category>
		<category><![CDATA[Cualificación Equipos de Laboratorio]]></category>
		<category><![CDATA[Cursos in company]]></category>
		<category><![CDATA[Farmacopea Europea]]></category>
		<category><![CDATA[GMP - GOOD MANUFACTURING PRACTICE]]></category>
		<category><![CDATA[GMP del Siglo XXI]]></category>
		<category><![CDATA[ICH Q11]]></category>
		<category><![CDATA[ICH Q9]]></category>
		<category><![CDATA[Laboratorio de Control]]></category>
		<category><![CDATA[Microbiología rápida]]></category>
		<category><![CDATA[Muestreo de materias primas]]></category>
		<category><![CDATA[OOS]]></category>
		<category><![CDATA[OOT]]></category>
		<category><![CDATA[QUALITY CONTROL]]></category>
		<category><![CDATA[RISK MANAGEMENT]]></category>
		<category><![CDATA[Risk Management Plan]]></category>
		<category><![CDATA[Risk-based Manufacturing]]></category>
		<category><![CDATA[Seminarios de Formación Especializada]]></category>
		<category><![CDATA[TRAINING MANAGEMENT 2.0]]></category>
		<category><![CDATA[Test de esterilidad]]></category>
		<category><![CDATA[análisis de riesgos]]></category>
		<category><![CDATA[controles en proceso]]></category>
		<category><![CDATA[cualificación-de-instrumentos-analiticos]]></category>
		<category><![CDATA[EMA]]></category>
		<category><![CDATA[FDA]]></category>
		<category><![CDATA[Inspección GMP]]></category>
		<category><![CDATA[microbiología-rápida]]></category>
		<category><![CDATA[quality-risk-management]]></category>
		<category><![CDATA[risk-based quality control]]></category>

		<guid isPermaLink="false">http://www.fernandotazon.com.es/?p=1651</guid>
		<description><![CDATA[<a title="Programa Formación Risk-based Quality Control" href="http://www.fernandotazon.com.es/wp-content/uploads/2010/08/Programa-RBQC.pdf" target="_blank"><img class="alignleft size-thumbnail wp-image-1666" title="Programa Formación Risk-based Quality Control" src="http://www.fernandotazon.com.es/wp-content/uploads/2010/08/Programa-RBQC-128x170.jpg" alt="" width="128" height="170" /></a>]]></description>
			<content:encoded><![CDATA[<p><a title="Programa Formación Risk-based Quality Control" href="http://www.fernandotazon.com.es/wp-content/uploads/2010/08/Programa-RBQC.pdf" target="_blank"><img class="alignleft size-thumbnail wp-image-1666" title="Programa Formación Risk-based Quality Control" src="http://www.fernandotazon.com.es/wp-content/uploads/2010/08/Programa-RBQC-128x170.jpg" alt="" width="128" height="170" /></a>Luego del gran éxito que hemos tenido con el <a title="Risk-based Manufacturing" href="http://www.fernandotazon.com.es/2010/08/29/primer-seminario-sobre-risk-based-manufacturing/" target="_blank">Seminario de Junio sobre <em>Risk-based Manufacturing</em></a>, el <span style="color: #ff0000;"><strong>08 de Noviembre</strong></span> organizaremos en Barcelona <strong> </strong>la versión dirigida a los Laboratorios de Control de Calidad con el <a title="Programa Formación Risk-based Quality Control" href="http://www.fernandotazon.com.es/wp-content/uploads/2010/08/Programa-RBQC.pdf" target="_blank"><span style="color: #ff0000;"><strong>Seminario de Formación Especializada </strong>sobre<strong> </strong><strong><em>Risk-based Quality Control</em></strong></span></a>.</p>
<p>Desde hace tiempo, tanto EMA como FDA basan sus estrategias de inspección en el nivel de riesgo que presenta cada compañía farmacéutica (<strong><em>Risk-based Inspections</em></strong>) y esperan que los laboratorios inspeccionados sean capaces de demostrar que conocen y controlan los riesgos asociados a sus laboratorios de control de calidad (<strong><em>Risk-based Quality Control</em></strong>).</p>
<p><strong>Para la industria farmacéutica</strong>, por otra parte, el poder equilibrar la carga de trabajo necesaria, el nivel de formalidad requerido y la cantidad de documentación a generar, con el nivel real de riesgo del producto, método o instrumento, supone un importante ahorro en recursos y permite focalizar los escasos medios disponibles sobre los factores críticos que aportan valor.</p>
<p>Este Seminario de Formación Especializada tiene tres objetivos bien definidos:</p>
<ol>
<li>Profundizar en la aplicación de los principios de gestión y prevención de riesgos</li>
<li>Analizar los requisitos para la integración práctica del <em>Quality Risk Management </em>en las actividades del Laboratorio de Control de Calidad</li>
<li>Estudiar la puesta en marcha en el laboratorio de control de calidad, de estrategias reales, basadas en la valoración y el control de los riesgos</li>
</ol>
<p>Los principales puntos del programa serán:</p>
<ol>
<li><strong><em>Quality Risk Management</em></strong>: Principios y conceptos fundamentales (<strong><span style="color: #993300;">Fernando Tazón Alvarez</span><em><span style="color: #666699;"> </span></em></strong><em><span style="color: #666699;">– Gerente Executive Consultant &#8211; <strong>ASINFARMA</strong></span></em>)</li>
<li><strong><em>Regulatory/Compliance</em></strong>: Visión de la Inspección Farmacéutica (<strong><span style="color: #993300;">Salvador Cassany</span><em> </em></strong><em><span style="color: #666699;">– Cap del Servei de Control Farmacèutic i Productes Sanitaris. <strong>Departament de Salut de la Generalitat de Catalunya</strong></span></em>).</li>
<li><strong><em>Risk-Based Quality Control </em>en la Cualificación de Instrumentos Analíticos</strong> (<strong><span style="color: #993300;">Ana Vila-Ferran</span><em><span style="color: #666699;"> </span></em></strong><em><span style="color: #666699;">– Directora General – <strong>MICRO BIOS</strong></span></em>)</li>
<li><strong><em>Risk-Based Quality Control </em>en el tratamiento de OOS</strong> (<strong><span style="color: #993300;">Dolors Solsona</span><em><span style="color: #666699;"> </span></em></strong><em><span style="color: #666699;">– Directora de Control Analítico &#8211; <strong>ESTEVE</strong></span></em>)</li>
<li><strong><em>Risk-Based Quality Control </em>en Microbiología Rápida</strong> (<strong><span style="color: #993300;">Rogelio Cortés</span><em><span style="color: #666699;"> </span></em></strong><em><span style="color: #666699;">– Responsable del Laboratorio de Microbiología – <strong>ALCON</strong></span></em>)</li>
<li><strong><em>Risk-Based Quality Control </em>en Controles en Proceso</strong> (<span style="color: #993300;"><strong>Daniel Pons</strong></span><em><span style="color: #666699;"> – Responsable QA Compliance &amp; Regulatory <strong>NOVARTIS</strong></span></em>)</li>
</ol>
<p>Mas información en <a href="http://www.asinfarma.com/">www.asinfarma.com</a>.</p>
<p>Contacto e inscripciones: Tel.: 618.519.468  y  email: <a href="mailto:asinfarma@asinfarma.com">asinfarma@asinfarma.com</a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.fernandotazon.com.es/2010/08/29/formacion-risk-based-quality-control/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Muestreo de materiales de acondicionamiento</title>
		<link>http://www.fernandotazon.com.es/2008/11/09/muestreo-de-materiales-de-acondicionamiento/</link>
		<comments>http://www.fernandotazon.com.es/2008/11/09/muestreo-de-materiales-de-acondicionamiento/#comments</comments>
		<pubDate>Sun, 09 Nov 2008 16:20:09 +0000</pubDate>
		<dc:creator>Fernando</dc:creator>
				<category><![CDATA[FDA]]></category>
		<category><![CDATA[Muestreo de materias primas]]></category>
		<category><![CDATA[Novedades FDA]]></category>
		<category><![CDATA[Quality Assurance]]></category>
		<category><![CDATA[artículos de acondicionado]]></category>
		<category><![CDATA[cGMP]]></category>
		<category><![CDATA[cierres]]></category>
		<category><![CDATA[condiciones de toma de muestras]]></category>
		<category><![CDATA[contenedores]]></category>
		<category><![CDATA[envases]]></category>
		<category><![CDATA[material de acondicionamiento]]></category>
		<category><![CDATA[material de envasado]]></category>
		<category><![CDATA[muestreo de artículos de acondicionado]]></category>
		<category><![CDATA[muestrero de material de acondiciomamiento]]></category>

		<guid isPermaLink="false">http://www.fernandotazon.com.es/?p=591</guid>
		<description><![CDATA[<img src="http://www.fernandotazon.com.es/wp-content/uploads/2008/11/packaging5-128x85.jpg" alt="" title="Material de envasado" width="128" height="85" class="alignnone size-thumbnail wp-image-594" />]]></description>
			<content:encoded><![CDATA[<p><img class="alignleft size-medium wp-image-594" title="Material de envasado" src="http://www.fernandotazon.com.es/wp-content/uploads/2008/11/packaging5-300x200.jpg" alt="" width="210" height="140" />La <a title="FDA Home Page" href="http://www.fda.gov/" target="_blank"><strong>FDA </strong></a>considera que realizar el examen a la recepción de contenedores, cierres y material de envasado en una <span style="color: #333399;"><strong>zona normal de almacén</strong></span>, no representa un riesgo para los materiales ni afecta la integridad de los resultados de la toma de muestras.</p>
<p>El requisito CGMP de que los contenedores “sean abiertos, muestreado y vueltos a cerrar de un modo que haya sido diseñado para evitar la contaminación de su contenido”, debe verse desde la óptica de que <span style="color: #333399;"><strong>to</strong><strong>do depende de las características de calidad que se pretendan para cada tipo de material que se esté muestreando, y de las condiciones ambientales del almacén</strong></span>.</p>
<p>La estrategia fundamental se basa en preservar siempre ambos requisitos, el criterio de “adecuado para el uso previsto” (<em>fitness for use</em>) para el material restante y la integridad de su calidad para la muestra extraída.</p>
<p>Con este criterio, el muestreo de contenedores y cierres que deban ser estériles o despirogenados, debe hacerse bajo condiciones equivalentes a la calidad pretendida para el material, por lo que, si luego han de ser examinados microbiológicamente, el ambiente del almacén no da suficiente seguridad.</p>
<p>El requisito mínimo es que todo muestreo se realice <strong>limitando la exposición al medio ambiente</strong>, tanto durante la extracción de la muestra, como luego de finalizada la operación (por ejemplo, limpiando las superficies exteriores, limitando el tiempo de apertura de los envases originales y volviendo a cerrar correctamente el embalaje original). Evidentemente, unos <strong>procedimientos </strong>bien escritos y respetados es un elemento esencial.</p>
<p>Las CGMP permiten al laboratorio, liberar un envío de contenedores y cierres, basándose en el certificado de análisis del proveedor, y en una identificación visual de los materiales. Una vez que se haya establecido la fiabilidad del proveedor mediante la validación de los resultados de sus controles, el laboratorio puede realizar la inspección visual totalmente en el almacén.</p>
<p><a title="Punto de vista de FDA" href="http://www.fda.gov/cder/guidance/cGMPs/component.htm#2" target="_blank"><strong>Aquí podéis encontrar el texto completo de este novedoso punto de vista de FDA.</strong></a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.fernandotazon.com.es/2008/11/09/muestreo-de-materiales-de-acondicionamiento/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>EMEA evalúa el uso de API’s que cumplen GMP</title>
		<link>http://www.fernandotazon.com.es/2008/08/26/emea-evalua-el-uso-de-api%e2%80%99s-que-cumplen-gmp/</link>
		<comments>http://www.fernandotazon.com.es/2008/08/26/emea-evalua-el-uso-de-api%e2%80%99s-que-cumplen-gmp/#comments</comments>
		<pubDate>Tue, 26 Aug 2008 16:26:26 +0000</pubDate>
		<dc:creator>Fernando</dc:creator>
				<category><![CDATA[Auditorías a Proveedores]]></category>
		<category><![CDATA[CONSULTORIA 2.0]]></category>
		<category><![CDATA[Cursos in company]]></category>
		<category><![CDATA[EMEA]]></category>
		<category><![CDATA[Inspección GMP]]></category>
		<category><![CDATA[Muestreo de materias primas]]></category>
		<category><![CDATA[QUALITY MANAGEMENT 2.0]]></category>
		<category><![CDATA[TRAINING MANAGEMENT 2.0]]></category>
		<category><![CDATA[APIs]]></category>
		<category><![CDATA[auditorias-a-fabricantes-de-principios-activos]]></category>
		<category><![CDATA[controles-de-materias-primas]]></category>
		<category><![CDATA[fabricantes-de-materias-primas]]></category>
		<category><![CDATA[GMP-para-APIs]]></category>

		<guid isPermaLink="false">http://www.fernandotazon.com.es/?p=301</guid>
		<description><![CDATA[<img class="alignnone size-thumbnail wp-image-302" title="Investigación de proveedores de materias primas" src="http://www.fernandotazon.com.es/wp-content/uploads/2008/08/investigacion5-128x191.jpg" alt="" width="128" height="191" />]]></description>
			<content:encoded><![CDATA[<p><img class="alignleft size-medium wp-image-302" style="float: left;" title="Investigación de proveedores de materias primas" src="http://www.fernandotazon.com.es/wp-content/uploads/2008/08/investigacion5-200x300.jpg" alt="Inspección de fabricantes de materias primas" width="134" height="202" />Entre Mayo de 2005 y Mayo de 2006, la <strong><a title="EMEA Home Page" href="http://www.emea.europa.eu/" target="_blank">EMEA </a></strong>ha realizado un estudio tendiente a determinar como los laboratorios cumplían con el requisito de utilizar solamente sustancias activas como materias primas, que hayan sido fabricadas de acuerdo con las GMP.</p>
<p>Como <strong>resultado </strong>se observó que la mayoría de las compañías inspeccionadas habían establecido un programa de auditorías a sus proveedores de API’s, aunque se detectaron algunas deficiencias, especialmente en compañías pequeñas. La frecuencia de problemas aumenta cuando se compran solo pequeñas cantidades, llegando a casos en los que la auditoría no fue aceptada por el proveedor.</p>
<p>Uno de los mayores <strong>problemas </strong>encontrados fueron discrepancias relacionadas con la trazabilidad y poder demostrar que la sustancia activa utilizada actualmente proviene del fabricante designado. Se vieron deficiencias relacionadas con cambios, reetiquetados y pérdida de documentación.</p>
<p>También han sido investigadas compañías <strong>comercializadoras </strong>y <strong>brokers</strong>, donde se encontraron problemas sustanciales. En algunos casos, los propios comercializadores creaban certificados de análisis, incluso se dio un caso de información errónea sobre el origen del principio activo. En cuanto a las auditorías realizadas por los propios comercializadores, se expresaron dudas relacionadas con conflictos de intereses (falta de independencia). El informe aporta información detallada sobre las actividades de comercializadores y brokers así como problemas derivados de ellos, particularmente la pérdida de trazabilidad.</p>
<p>La <strong>evaluación </strong>demuestra que los laboratorios farmacéuticos son conscientes de sus responsabilidades y toman medidas para cumplir con los requisitos. Es de esperar que en el futuro, la cualificación de proveedores continúe siendo un punto de especial atención.</p>
<p>En <strong><span style="font-size: 12pt; font-family: Arial; color: blue;">ASINFARMA</span></strong> tenemos amplia experiencia en desarrollar programas de cualificación de proveedores y en realizar auditorías de cumplimiento de GMP.</p>
<p><a title="EMEA: Uso de APIs que cumplen GMP" href="http://www.emea.europa.eu/Inspections/docs/36181908en.pdf" target="_blank">Aquí podéis bajar el informe completo.</a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.fernandotazon.com.es/2008/08/26/emea-evalua-el-uso-de-api%e2%80%99s-que-cumplen-gmp/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Ensayo de identificación y toma de muestras</title>
		<link>http://www.fernandotazon.com.es/2008/08/23/ensayo-de-identificacion-y-toma-de-muestras/</link>
		<comments>http://www.fernandotazon.com.es/2008/08/23/ensayo-de-identificacion-y-toma-de-muestras/#comments</comments>
		<pubDate>Sat, 23 Aug 2008 15:47:30 +0000</pubDate>
		<dc:creator>Fernando</dc:creator>
				<category><![CDATA[EMEA]]></category>
		<category><![CDATA[FDA]]></category>
		<category><![CDATA[Inspección GMP]]></category>
		<category><![CDATA[Muestreo de materias primas]]></category>
		<category><![CDATA[QUALITY MANAGEMENT 2.0]]></category>
		<category><![CDATA[Auditorías a Proveedores]]></category>
		<category><![CDATA[controles-de-materias-primas]]></category>
		<category><![CDATA[ensayos de identidad]]></category>
		<category><![CDATA[ensayos-en-materias-primas]]></category>
		<category><![CDATA[identificación de materias primas]]></category>
		<category><![CDATA[Inspección-Sanitaria]]></category>
		<category><![CDATA[muestras de materias primas]]></category>
		<category><![CDATA[muestreo]]></category>
		<category><![CDATA[principios-activos-farmacñeuticos]]></category>

		<guid isPermaLink="false">http://www.fernandotazon.com.es/?p=293</guid>
		<description><![CDATA[<img class="alignnone size-thumbnail wp-image-296" title="Toma de muestras" src="http://www.fernandotazon.com.es/wp-content/uploads/2008/08/analisis9-128x82.jpg" alt="" width="128" height="82" />]]></description>
			<content:encoded><![CDATA[<p><a href="http://www.fernandotazon.com.es/wp-content/uploads/2008/08/analisis9.jpg"><img class="alignleft size-medium wp-image-296" style="float: left;" title="Toma de muestras" src="http://www.fernandotazon.com.es/wp-content/uploads/2008/08/analisis9-300x193.jpg" alt="" width="152" height="97" /></a>Una de las preguntas más frecuentes que hacen muchos laboratorios, está relacionada con la identificación de principios activos y excipientes.</p>
<p>¿Cuántos contenedores, de cada componente de un envío, se deben muestrear y controlar para cumplir con el requisito GMP del ensayo de identificación?<br />
¿Se puede hacer el ensayo de identificación sobre una muestra formada por la mezcla de múltiples contenedores?</p>
<p>La <a title="FDA Home Page" href="http://www.fda.gov/default.htm" target="_blank"><strong>FDA </strong></a>acaba de dar una respuesta detallada a estas preguntas.</p>
<p>Las GMP no especifican el número de contenedores de los que deben tomarse muestras, sin embargo, una toma de muestras correcta debe cumplir los siguientes requisitos:</p>
<ul>
<li>Las muestras deben ser representativas</li>
<li>El número de contenedores de los que deben tomarse muestras y las cantidades a muestrear deben basarse en criterios estadísticos, teniendo en cuenta la variabilidad de los materiales, los intervalos de confianza y el nivel de precisión necesario.</li>
<li>Los planes de muestreo deben tener en cuenta la historia de calidad del proveedor.</li>
<li>La cantidad de material a tomar debe ser suficiente para realizar los análisis y conservar una contramuestra.</li>
</ul>
<p>Cada laboratorio debe desarrollar un programa que garantice, con un alto nivel de confianza, que cada contenedor contiene exactamente el material indicado en la etiqueta.</p>
<p>Las GMP permiten al laboratorio tomar sus propias decisiones sobre cuantas muestras son necesarias para realizar el ensayo de identidad, teniendo en cuenta que, en el caso de materiales comprados a una empresa distribuidora, es aconsejable tomar una muestra de cada contenedor individual.</p>
<p>También establecen que las muestras deben tomarse luego de la recepción del material, por lo que muestras tomadas antes del envío de la mercancía (las llamadas <em>“piggyback” samples</em>) no son generalmente aceptables.</p>
<p>El combinar o aunar muestras de varios contenedores se considera posible, ya que no existe una prohibición general de unificar muestras de diferentes contenedores</p>
<p>Estas definiciones de FDA cumplen en muchos puntos con los requisitos de las GMP UE y el <a title="Anexo 8 GMP UE" href="http://www.agemed.es/actividad/sgInspeccion/docs/21-anexo8.pdf" target="_blank">Anexo 8</a> para el muestreo de materiales de partida.</p>
<p><a title="Muestras y ensayo de identidad" href="http://www.fda.gov/cder/Guidance/cGMPs/component.htm#4" target="_blank">Aquí os dejo el link al texto original.</a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.fernandotazon.com.es/2008/08/23/ensayo-de-identificacion-y-toma-de-muestras/feed/</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
	</channel>
</rss>

